Battery undervoltage protection BP-100i 12/24V 100A

Undervoltage protection disconnects the load from the batteries before the battery is completely discharged, which could quickly destroy the battery. Or it disconnects the battery before it has enough power to start the engine.


12/24V automatic setting.
BatteryProtect automatically detects the system voltage and adjusts to it.


BatteryProtect can be set to ten different connection and disconnection voltages from/to the battery.


Special settings for Li-Ion batteries
In this mode, BatteryProtect can be controlled via the VE.Bus BMS.


Very low power consumption
Low consumption is very important for Li-ion batteries, especially after switching off at low voltage.


Overvoltage protection.
BatteryProtect has a built-in overvoltage protection function, disconnects the load at a voltage of 16V or 32V.


No sparks.
The design of the undervoltage protection is an encapsulated MOSFET, so there is no sparking on the switching elements.


Output for alarm with delay.
This output can be used to power the alarm if the voltage drops below the set limit for a period longer than 12s. Therefore, starting the engine does not activate the alarm. It is typically used to turn on an alarm or light, but it can also be used to turn on a charger or generator. The relay output is max 500mA.


Load disconnection with delay - after 90s from the alarm, the load will be disconnected, if the voltage increases during this time (alternator start, charger, etc.) the disconnection will not be activated.


TECHNICAL PARAMETERS
Maximum continuous current: 100A
Peak current: 600A
Working voltage: 6-35V
Alarm delay: 12s
Consumption: when the protection is closed: 1.5mA, when it is open or off at low voltage: 0.6mA
Load connection delay: 90s, (immediately if caused by VE.Bus BMS)
Standard disconnection settings: 10.5 or 21V, Connection: 12 or 24V
Weight: 0.6Kg
Dimensions: 59 x 42 x 115 mm