Change language CZ Zmeniť jazyk SK Sprache ändern DE Change language EN
Number: 0 0,00 EUR

Victron Energy Battery undervoltage protection BP-65i 12/24V 65A

click to enlarge
Victron Energy Battery undervoltage protection BP-65i 12/24V 65A
Victron Energy Battery undervoltage protection BP-65i 12/24V 65A
Product no longer available
code:bp-65i
Manufacturer:Victron Energy
Price with VAT : 45,50 EUR
Price without VAT : 37,60 EUR
VAT:21 %
availability:on inquiry

Battery undervoltage protection BP-65i 12/24V 65A

The undervoltage protection disconnects the load from the batteries before the battery is completely discharged, which could quickly destroy the battery. Or it disconnects the battery before it has enough power to start the engine.


12/24V automatic setting.
BatteryProtect automatically detects the system voltage and adjusts to it.


BatteryProtect can be set to ten different connection and disconnection voltages from/to the battery.


Special settings for Li-Ion batteries
In this mode, BatteryProtect can be controlled via the VE.Bus BMS.


Very low energy consumption
Low consumption is very important for Li-ion batteries, especially after switching off at low voltage.


Overvoltage protection.
BatteryProtect has a built-in overvoltage protection function, it disconnects the load at a voltage of 16V or 32V.


No sparks.
The design of the undervoltage protection is an encapsulated MOSFET, so there is no sparking on the switching elements.


Output for alarm with delay.
This output can be used to power the alarm if the voltage drops below the set limit for a period longer than 12s. Therefore, starting the engine does not activate the alarm. It is typically used to turn on an alarm or light, but it can also be used to turn on a charger or generator. Relay output is max 500mA.


Disconnection of the load with a delay - after 90 seconds from the alarm, the load will be disconnected, if during this time there is an increase in voltage (start of the alternator, charger, etc.), the disconnection will not be activated.


TECHNICAL PARAMETERS
Maximum continuous current: 65A
Peak current: 300A
Working voltage: 6-35V
Alarm delay: 12s
Consumption: if the protection is switched on: 1.5mA, if it is disconnected or switched off at low voltage: 0.6mA
Load connection delay: 90s, (immediately if caused by VE.Bus BMS)
Standard disconnection settings: 10.5 or 21V, Connection: 12 or 24V
Weight: 0.2 kg
Dimensions: 40 x 48 x 106mm

 

do you need advice? Victron Energy Battery undervoltage protection BP-65i 12/24V 65A

Brand                                             
type  
Your first name, last name, company
Your email
Your telephone number
You Enquiry
     More information
I agree with the processing of my personal data to process my query